Brand Name :ATMARS
Model Number :AS3-72 SERIES
Certification :ISO, CE
Place of Origin :Guangdong, China
MOQ :1 Set
Price :Negotiable
Payment Terms :L/C, T/T, Western Union
Supply Ability :35 Sets Per Month
Delivery Time :25 Working Days
Packaging Details :Wooden Box
Capacity :72L
Orientation :Horizontal / Pneumatic Damper Transfer
Temp. Zone :Hot, Cold and Selectable Ambient
Power Supply :3 Phase, 380V, 50Hz
Application :Air to Air Thermal Shock Test
Product Name :Thermal Shock Chamber
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

3 Zone Small Thermal Shock Chamber For Labs Shock Test 3 Phase 380V 50Hz


Electrical
All circuits fused or circuit breaker protected
All wiring labeled or color coded
Fully enclosed electrical panel
High Temperature limit safety
Balanced load on 3 phase power
What is a Three -Zone Thermal Shock Chamber ?
3-Zone Thermal Shock Chambers from ATMARS has three side-by-side independent zones: hot, ambient, and cold. The addition of the ambient zone allows for three zone testing, which is a requirement of some military standards.

General Performance of ATMARS Three Zone Thermal Shock Test Chambers
AS3 Series Three Zone (Hot/Ambient/Cold) Horizontal Layout (side by side) - direct hot/cold transfer with selectable ambient temperature dwell required for some MIL-STD's.
Our standard three-zone thermal shock chambers models workspace volumes include: 72L, 100L, 150L, 200L, 252L, 300L and 480L. And interior dimensions can be customized according to specimen sizes and your testing requirements.
Temperature Range:
- Hot zone to +180℃ (356° F)
- Cold zone to -75℃ (-103° F)
- Other temperature range available
High temperature exposure: +150℃ (302° F)
Low temperature exposure:
Type A: -40℃ (-40° F)
Type B: -55℃ (-67° F)
Type C: -65℃ (-85° F)
Recovery time for mechanical refrigeration : ≤ 5minutes
High / Low temperature exposure time: 30minutes
An ATMARS application engineer can assist you in selecting the chamber configuration and size that is most economical for your testing needs.

Techinical Specifications of AS3-72 SERIES THREE-ZONE Thermal Shock Test Chambers
Performance is based on ambient temperature +25 ℃ or circulating water temperature +25 ℃, empty load no specimen.
ModelAS3-
72A72B72C
PerformanceTemperature Range-55℃ to +180℃-70℃ to +180℃-75℃ to +180℃
Temperature Fluctutation≤±0.5℃ (at a steady temperature)
Temperature Uniformity≤±1.5℃
Temperature Deviation≤±1.5℃
Temperature Overshoot≤±2.0℃
Thermal Shock Temp. Range-40℃ to +150℃
Hot: +60℃ to +150℃
Cold: -40℃ to -10℃
-55℃ to +150℃
Hot: +60℃ to +150℃
Cold: -55℃ to -10℃
-65℃ to +150℃
Hot: +60℃ to +150℃
Cold: -65℃ to -10℃
Test Room Temp. Range-40℃ to +150℃-55℃ to +150℃-65℃ to +150℃
Transfer Time10 Sec.
Recovery Time≤5min.
Hot Zone Temp. Range+60℃ to +180℃
Preheating Time+60℃ to +180℃ in 30min.
Exposure Time30min.
Cold Zone Temp. Range-55℃ to -10℃-70℃ to -10℃-75℃ to -10℃
Precooling Time+20℃ to -55℃ in 45min.+20℃ to -70℃ in 45min.+20℃ to -75℃ in 45min.
Exposure Time30min.
Workspace Volume72L
Workspace Dimensions (WxDxH)mm500500500
360360360
400400400
Exterior Dimensions (WxHxD)mm160016001600
166016601660
185018501850
MaterialInterior#SUS304 stainless steel
SealImported silicone seal
InsulationExpanded foam & fiberglass
ExteriorCold-rolled steel with powder coated surface
SystemHeatingNichrome resistance wire heater
RefrigerationMechannical refrigeration system
ControlPLC Touch-screen Controller
Noise Level≤70dB (A-weighted sound pressure level measured at a distance of 1.0 meter)
Allowable Ambient ConditionsTemperature: +5℃ to +35℃;
Relative humidity: ≤85%RH (No condensation);
Air pressure: 86kPa to 106kPa.
Power SupplyAC 380 (1±10%)V (50±0.5)Hz 3 Phase 4 Wire plus Earth Wire
Cusom options are available.


Outstanding Features of Three-Zone Thermal Shock Chambers AS3-72 SERIES

Cabinet
Welded #SUS304 stainless steel interior
Cold-rolled steel exterior with powder coated finish
Welded structural base frame with removable service access panel on three sides for easy maintenance
Chamber drain
Direct drive-shaft powered forced air circulation
No need to move specimen, hot/cold thermal shock by pneumatic dampers
Low "K" factor urethane foam insulation and fiberglass thermal insulation
Full opening chamber door with dual silicone sealing gaskets
Front built-in touch-screen programmable controller
Chamber fan motors externally located
Through-wall traveling access port
Stainless steel shelves
Heavy duty casters and floor stands for mobility and balance
Make modifications to structure when necessary allowing for a modular assembly on-site overcome most facility issues

Heating / Airflow / Cooling Systems
Efficient open wire nichrome resistance heaters
Forced interior air circulation with efficient fan motors
Self-contained Single stage or cascade mechanical refrigeration system
- France TECUMSEH hermetic reciprocating compressor
- German GEA (Bock) semi-hermetic reciprocating compressor
- German BITZER semi-hermetic reciprocating compressor
- USA Copeland hermetic compressor
Zero ozone depletion potential (ODP) refrigerants - R404A / R23
Air cooled condenser / Water Cooled Condenser (Option) / Option Liquid Nitrogen Cooling
High efficiency brazed plate heat exchanger (Option)
EMERSON A-W Series oil separators
Solenoid valves for energy saving refrigeration bypass capacity control
All piping joints silfosed or silver soldered
Oil pressure switches


Optional Accessories
Custom colors
Number, size, position and shape (round, glove or square) of traveling access ports
Additional shelves
Custom fixture
Door Interlocks
Water cooled condenser
Remote refrigeration system
Boost cooling system, LN2 or CO2
Dry air purge
Dry nitrogen purge
Quiet package

3 Zone Small Thermal Shock Chamber For Labs Shock Test 3 Phase 380V 50Hz





















































































Inquiry Cart 0